Project Profile
- Project Location : New York
- Client Industry : Utility
- Owner Industry : Contractor/Consultant
- Gwtt Scope : Design, Build, O&M
- Contract Value : $0.9M
- Project Duration : 5 Months
- Contaminants : Oil and Grease
Key Project Details
- Two independent treatment systems with oil separators, bag filters, and granular activated carbon units
- GWTT’s role was to design, build, and provide O&M
- Both systems were fully winterized for operation through winter months
- Effluent limit was 10ppm oil/grease at 500 GPM
PROJECT CHALLENGES
- The project site was an electrical substation that required safety procedures and protocols that were far more complex and detailed than similar work on a non-electrical infrastructure site
- The project site had high levels of ambient voltage which made troubleshooting and testing electrical panels and other low-voltage equipment more difficult and time consuming
Project Narrative
GWTT designed, built, installed, and operated two 500 GPM oil/water separator treatment systems on a single project site in New York. Systems’ design met effluent criteria of 10ppm oil and grease at full flow-rate specification. Each system consisted of an oil/water separator, transfer pumps, bag filters, and a 10,000-lb granular activated carbon unit. The systems discharged to a local manhole.
The systems were installed and connected to the site existing drainage basin and discharge point via HDPE piping. Automatic controls were built into the systems to prevent exceeding any pressure or level limits of the treatment components.
Both systems were prefabricated in shipping containers at GWTT’s equipment fabrication facility in Wharton, NJ. GWTT set the treatment systems in place utilizing a 65-ton crane and ran HDPE piping from the client’s drainage basin to the systems’ carbon units and discharge point.
Systems’ operation and maintenance was performed by GWTT staff.